Ou Shisheng High-Throughput Self-Driving Experimental Platform: One Platform for Three Reaction Systems
Most laboratories typically purchase separate hardware for different reaction types. This includes dedicated photoreactors for photocatalytic screening, pressure-resistant reactors for pressurized thermocatalysis, and independent setups for conventional organic synthesis. However, having these separate, discrete equipment layouts creates several problems. First, managing separate operating protocols and scattered experimental data increases the overall burden of laboratory management. Second, when comparing the same catalyst under both photocatalytic and thermocatalytic conditions, inconsistent parameters such as reaction temperature, atmosphere, and sampling methods across different instruments lead to systematic deviations from the start. This compromises the reliability of comparative results.
The Ou Shisheng High-Throughput Self-Driving Experimental Platform combines three types of reaction systems into a single experimental workflow. Each reaction module has its own feeding, temperature control, and reaction units specifically designed for its type of reaction. However, these modules share a common post-treatment unit, including a positive-pressure filtration system, an automated guided vehicle (AGV) transfer station, and a detection station. AGVs transport samples to the analysis station, allowing for unattended operation from sample feeding all the way to data output. A unified software workstation ensures consistent experimental conditions and centralizes data archiving. Experimental parameters are set uniformly, and process parameters, raw spectra, and results are all linked to the same batch according to standardized metadata. This creates a traceable data lineage. The hardware guarantees stable experimental execution, while the software facilitates cross-comparison of datasets and the feedback of data to AI models. This approach fundamentally resolves inconsistencies in experimental conditions and data.

Ou Shisheng High-Throughput Self-Driving Experimental Platform
01 Platform Components: One Integrated Platform, Three Reaction Units, One Robot, One Analysis Unit
The entire platform comprises three reaction modules, an AGV robotic arm, and supporting analysis equipment. The primary distinction between the three reaction modules lies in their reaction cells:
· Synthesis Unit: Designed for organic synthesis at atmospheric pressure under an inert atmosphere, featuring 36 parallel reaction positions.
· Thermocatalysis Unit: Equipped with 18 atmospheric-pressure reaction positions and an 8-channel high-pressure reaction module.
· Photocatalysis Unit: Configured with 3 photoreactors, each having 8 independent reaction channels and interchangeable light sources.
Internal material transfer within each module is managed by built-in robotic arms. Sample transfer between different modules is handled by the AGV robot, enabling connections between stations. The AGV can transport entire sample trays to the analysis area or deliver individual vials to the inlets of instruments like gas chromatographs. The detection module can interface with users’ existing UV-Vis spectrometers, gas chromatographs, and other instruments, automatically selecting the appropriate detection workflow for different catalytic reactions.
All reaction modules are operated within fume hoods. All wetted components are constructed from glass, PTFE, or 316L stainless steel. These materials are compatible with common organic solvents, including dichloromethane, toluene, and DMF, as well as acidic and alkaline solutions such as organic acids and sodium hydroxide.
02 Entire Workflow: From Reagent Storage to Analysis Station
Let's trace a complete run for a single sample using the synthesis unit as an example. The workflow involves nine steps. Dosing and sampling are performed for each individual well, while sealing, temperature control, and filtration are done in batches for the entire tray. An AGV transports the trays, and the workflow can be edited autonomously based on experimental needs.
Workflow Overview: Material Preparation → Solid Dosing → Liquid Dosing → Sealing & Gas Purge → Temperature-Controlled Reaction → Sampling & Dilution → Positive-Pressure Filtration → AGV Transfer → Instrument Analysis
Material Preparation: Solid reagents are loaded into material hoppers, liquid reagents and solvents are placed in designated storage positions, and reaction vials are loaded onto trays. All materials needed for an entire experimental batch are prepared at one time.
Solid Dosing: A negative-pressure feeder aspirates the specified amount of powder. Real-time weighing data is fed back from the balance. An electrostatic eliminator neutralizes the powder's static electricity before feeding to prevent charged particles from affecting weighing accuracy.
Liquid Dosing: A four-channel pipettor dispenses microscale liquid reagents well by well. Simultaneously, a pumping system delivers solvents. A capping/decapping mechanism automatically opens and closes reagent vials, resealing them immediately after dosing to minimize solvent evaporation and cross-contamination.
Sealing and Gas Purge: The entire tray of reaction vials is moved to the reaction station for batch sealing and gas exchange. The synthesis unit performs inert gas purging. The thermocatalysis and photocatalysis units maintain the configured target reaction gas atmosphere.
Temperature-Controlled Reaction: Temperature control and stirring begin simultaneously. Each reactor is divided into multiple temperature zones, allowing parallel operation at different temperature set points within a single batch of experiments.
Sampling and Dilution: Once the reaction is complete, the entire tray moves to an intermediate station for cooling. A pipettor then precisely dispenses the reaction liquid from each vial. Following this, a diluent is added in batches to adjust the sample concentrations to the range required for detection.
Positive-Pressure Filtration: Positive pressure pushes the diluted sample through a filter membrane into a receiving vial in a single step. The liquids from individual wells remain separate, preventing cross-contamination that could arise from the filtration sequence.
AGV Transfer: The robotic arm places the filtered sample into chromatographic vials or cuvettes. Subsequently, the AGV transports the complete sample tray from the reaction module to the analysis module.
Instrument Analysis: The AGV delivers individual vials to the instrument's inlet. Spectrometers and chromatographs then automatically handle sample injection, detection, and result analysis. All test data is centrally archived by the software. This marks the completion of the full sample workflow, from the initial solid powder to the final analysis results.
03 Five Key Features Expandable for New Reaction Types by only Switching the Reaction Unit
The three reaction platforms include complete feeding, sampling, filtration, and other functional units built to a unified specification, allowing them to operate independently. Sample detection is centrally managed by the AGV and the detection platform. To accommodate new reaction types in the future, only the corresponding reaction unit needs to be connected to the main framework. Existing operating procedures, data pipelines, and experimental workflows can be migrated and reused, significantly reducing the cost of redeveloping and validating new Standard Operating Procedures (SOPs).
Self-Optimizing Solid Dosing Database
Weighing milligram quantities of solids presents a major challenge for high-throughput automation. Powder flowability, static electricity, and bulk density all directly impact dosing accuracy. The platform features a built-in material database that builds dosing accuracy models for different substances and enables self-optimization. As experimental data accumulates, dosing accuracy and stability continuously improve. This transforms solid dosing, which traditionally relies heavily on manual operation, into a trainable, quantifiable, and standardized procedure.
Closing the Control Loop for Two Challenging Parameters: Light Irradiation and Pressure
For photocatalysis experiments, the photoreactors support interchangeable narrow-band and broadband white light sources with adjustable power. The power for each reaction channel can be set independently. Heat generated by illumination is managed through coordinated active air cooling and oil bath temperature control, preventing light-induced thermal drift from affecting experimental results. For thermocatalysis, the high-pressure reaction unit maintains the target pressure in real-time using electronic pressure controllers. Multiple reaction gases can be purged and replenished as needed. Pressure and gas composition become controlled variables with defined accuracy specifications, managed at the same control level as temperature.
Automated Post-Treatment: The Real Bottleneck of High-Throughput Workflows
Post-reaction sampling, dilution, and filtration are key bottlenecks that limit the efficiency of high-throughput experimentation. This platform automates the entire workflow, including quantitative sampling, batch dilution, and positive-pressure filtration. Isolated filtration wells completely eliminate cross-contamination risks, ensuring reliable data for parallel experiments.
Unified Data Pipeline for Model-Reusable Experimental Records:
The three reaction modules share a common task scheduler and metadata specifications. Experimental schemes, weighing logs, temperature and pressure control profiles, raw spectra, and test results are automatically linked under a single batch ID. Failed experiments and abnormal operating conditions are also archived, ensuring that negative samples are retained. These structured datasets support manual review and can be used to train models, guiding the design of subsequent experimental runs.
04 Applicable Reaction Systems and Expansion Capability
Classified by supported reaction types, the synthesis module handles synthetic reactions at atmospheric pressure and under an inert atmosphere. The thermocatalysis module supports gas-solid catalytic reactions at ambient and elevated pressures. The photocatalysis module enables photocatalytic screening within visible and ultraviolet wavelength ranges. Samples generated from these three reaction systems converge into a unified workflow for detection and data archiving.
Built on a modular, stackable architecture, the platform includes expansion interfaces for online pH monitoring, automated filtration, and integration with additional analytical instruments. It also embeds a reagent inventory and consumable management module to standardize the classified disposal of liquid and solid waste. For future scaling, newly added functional modules can be directly integrated into the existing platform framework.
The Ou Shisheng High-Throughput Self-Driving Experimental Platform moves beyond the conventional approach that requires separate, standalone instruments for photocatalysis, thermocatalysis, and organic synthesis. With modular hardware integration and end-to-end automation, it connects the entire workflow, from dosing and reaction to post-treatment and detection. Experimental parameters, operating logs, and results, previously scattered across multiple instruments, are now centralized and managed uniformly.
This approach eliminates systematic deviations caused by disparate hardware setups, ensuring reliable data for comparative tests of catalysts across different systems. Furthermore, standardized, structured full experimental records provide a strong foundation for manual recipe iteration and AI-driven closed-loop autonomous experimentation. This enables catalytic and synthetic chemistry research to embrace a new R&D paradigm that is high-throughput, reproducible, and self-driving.
05 Appendix: Platform Specifications
|
High-ThroughputSelf-DrivingExperimentalPlatformSpecifications |
||||||||
|
Platform/Unit |
Item |
Specification |
Platform/Unit |
Item |
Specification |
Platform/Unit |
Item |
Specification |
|
Synthesis Platform |
Solid Weighting Range |
0.1 mg-220 g |
Thermocatalysis Reaction Platform |
Solid Weighting Range |
0.1 mg-220 g |
Photocatalysis Reaction Platform |
Solid Weighting Range |
0.1 mg-220 g |
|
Solid Dosing Precision |
±0.1 mg |
Solid Dosing Precision |
±0.1 mg |
Solid Dosing Precision |
±0.1 mg |
|||
|
Solid Hoppers |
10 个 × 15 mL,with static eliminators |
Solid Hoppers |
10 个 × 15 mL,with static eliminators |
Solid Hoppers |
10 个 × 15 mL,with static eliminators |
|||
|
Dosing Tip |
0.02-0.624 mL |
AI |
Autonomous learning for material library and dosing models |
AI |
Autonomous learning for material library and dosing models |
|||
|
Negative Pressure Feeder |
<15 s per dose,±3% accuracy |
Pipettor |
4-channel independent pipettor, full-scale error ≤1% |
Pipettor |
4-channel independent pipettor, full-scale error ≤1% |
|||
|
AI |
Autonomous learning for material library and dosing models |
Tip |
0.02 / 0.2 / 1 mL |
Tip |
0.02 / 0.2 / 1 mL |
|||
|
Pipettor |
4-channel independent pipettor, full-scale error ≤1% |
Four-Plunger Valve-Free Bi-Directional Metering Pump |
Qty: 2 Flow: 0.05–20 mL/min, Accuracy ±0.2%, Repeatability 0.05%, Displacement: 600 μL |
Syringe Pump |
Volume 25 mL ,Accuracy ±5 μL |
|||
|
Tip |
0.02 / 0.2 / 1 mL |
Number of Reaction Positions |
18 ambient-pressure reaction positions |
PhotoReactor |
3 sets × 8 channels, 2 temperature zones |
|||
|
Syringe Pump |
Flow Rate: 0.001~9.999 mL/min, Accuracy ±1%, Repeatability RSD 0.29% |
Ambient-Position Temperature Control |
Ambient–100 ℃, Accuracy ±1 ℃ |
Reaction Vial |
20 mL, ambient pressure |
|||
|
Number of Reaction Positions |
6 ambient-pressure reaction positions |
Ambient-Position Oil Bath |
-20–100 ℃, Accuracy ±1 ℃ |
Gas Types |
3 |
|||
|
Reaction Vial Volume |
10 mL |
Stirring Speed |
Max. 1,200 rpm |
Light Source |
Interchangeable narrow-band 255–760 nm / broadband white LED |
|||
|
Inert Gas Purge |
Automatic inert gas exchange |
Reaction Vial Volume |
10 mL |
Light Source Adjustment |
Power adjustable, per-channel independent control |
|||
|
Temperature Control Accuracy |
±1 ℃ |
High-Pressure Unit |
2 high-pressure stirred reactors, 4 channels each |
SamplePlat Light Intensity |
>800 mW/cm² |
|||
|
Heating Method |
Electric heating: Ambient - 100 ℃; Oil bath: 0 - 100 ℃ |
High-Pressure Vial |
10 mL |
Temperature Control |
-20–100 ℃, ±1 ℃ accuracy |
|||
|
Stirring Speed |
Max. 1,200 rpm |
High-Pressure Temperature |
Ambient–100 ℃ |
Stirring Speed |
>1,000 rpm |
|||
|
Reaction Vial Sealing |
Self-locking cap, pressure rating 0.1 MPa |
High-Pressure Pressure |
1 MPa, control accuracy ±0.01 MPa |
Heat Dissipation |
Active air cooling for light sources |
|||
|
Filtration Unit |
Dilution Factor |
10-200 |
||||||
|
Filtration Method |
Positive-pressure filtration |
|||||||
|
Filter Membrane |
0.22 μm, disposable filter assembly |
|||||||
|
Stations |
24 / 36 positions |
|||||||
|
Pressure |
10 kPa |
|||||||